Part Number : 6181559-006
Alternate P/N : 6181559006
NSN : 5915013288561
Item Name : Filter Radio Freque
Manufacturer : Raytheon Company
CAGE Code : 15090
FSC Details : 5915 filters and networks
Good news! Part number 6181559-006 with NSN 5915013288561 by Raytheon Company is available and ready to ship. NSN Sourcing, owned and operated by ASAP Semiconductor, offers the fastest lead times in the industry. If you are interested in ordering part number 6181559-006, leave your procurement process to us. Simply fill out the fields in the RFQ below. Your responses to the asterisk (*) marked fields are necessary in order to build your quote possible.
As a globally trusted distributor, our comprehensive inventory is unmatched across the aerospace and aviation, marine, railway, and defense industries. Owned and operated by ASAP Semiconductor, we have more than 10 million National Stock Numbers (NSN) in our ready-to-ship inventory. Our company is committed to quality, and we operate as an AS9120B, ISO 9001:2015, and FAA AC 0056B certified company.
Note : We will not share your information to any third parties.
With locations in the US, we provide an optimized purchasing solution to get the parts you need, when you need them. We have dedicated offices in California and Nevada.
A National Stock Number, or NATO Stock Number (NSN), is allocated by the Defense Logistics Agency (DLA) and suggests that an item is procured, stocked, and issued through the federal supply system. The NSN part 6181559-006 is recognized by the United States Department of Defense and the North Atlantic Treaty Organization (NATO). Not sure if this is what you’re looking for? No problem. To receive more information about NSN Number 5306015721907, please contact us at our toll-free number +1-714-705-4780 or email us at sales@nsn-sourcing.com.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-328-8561 Item Description: Filter Radio Freque | 5915 | 013288561 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | G | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6181559-006 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.155 INCHES MINIMUM AND 2.219 INCHES MAXIMUM |
AFGA | OPERATING TEMP RANGE | -55.0/+125.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 6TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 4TH RADIO INTERFERENCE AND 8.0 VOLTS DC 4TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 6TH RADIO INTERFERENCE AND 8.0 VOLTS DC 6TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 59610 |
AHBP | INPUT TERMINAL IDENTIFICATION | MIL-C-26482 |
AHBS | OUTPUT TERMINAL MANUFACTURER CODE | 59610 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION AND 800.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION AND 800.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION AND 800.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION AND 800.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION AND 800.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQRG | BODY MATERIAL | ALUMINUM |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 1.2 KILOVOLTS AT SEA LEVEL |
CRST | BODY SURFACE TREATMENT | GOLD |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 1ST RADIO INTERFERENCE AND 8.0 VOLTS DC 1ST RADIO INTERFERENCE |
AHBT | OUTPUT TERMINAL IDENTIFICATION | MIL-C-26482 |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 32 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT |
FEAT | SPECIAL FEATURES | THIRTY-TWO FILTERED FUNCTIONS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 5TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 6TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 5TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 2ND RADIO INTERFERENCE AND 8.0 VOLTS DC 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 3RD RADIO INTERFERENCE AND 8.0 VOLTS DC 3RD RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 5TH RADIO INTERFERENCE AND 8.0 VOLTS DC 5TH RADIO INTERFERENCE |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION AND 800.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
PRMT | PRECIOUS MATERIAL | GOLD |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
CBBL | FEATURES PROVIDED | MOUNTING BRACKET AND SHOCK RESISTANT |
CQDZ | MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 1.2 KILOVOLTS AT SEA LEVEL |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD |
STYL | STYLE DESIGNATOR | FILTER CONNECTOR |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.