AS9120B, ISO 9001:2015, and FAA 0056B Accredited

CNA 2001-05 Part with NSN 5915-01-331-3906 by Pacific Aerospace And Electronics Inc - Request a Competitive Quote Now

Part Number : CNA 2001-05

Alternate P/N : CNA200105

Item Name : Filter Radio Freque

CAGE Code : 66230


Good news! Part number CNA 2001-05 with NSN 5915013313906 by Pacific Aerospace And Electronics Inc is available and ready to ship. NSN Sourcing, owned and operated by ASAP Semiconductor, offers the fastest lead times in the industry. If you are interested in ordering part number CNA 2001-05, leave your procurement process to us. Simply fill out the fields in the RFQ below. Your responses to the asterisk (*) marked fields are necessary in order to build your quote possible.

As a globally trusted distributor, our comprehensive inventory is unmatched across the aerospace and aviation, marine, railway, and defense industries. Owned and operated by ASAP Semiconductor, we have more than 10 million National Stock Numbers (NSN) in our ready-to-ship inventory. Our company is committed to quality, and we operate as an AS9120B, ISO 9001:2015, and FAA AC 0056B certified company.

Note : We will not share your information to any third parties.

PRODUCT DETAILS “*” Required fields are compulsory

CONTACT INFORMATION

  * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

With locations in the US, we provide an optimized purchasing solution to get the parts you need, when you need them. We have dedicated offices in California and Nevada.

A National Stock Number, or NATO Stock Number (NSN), is allocated by the Defense Logistics Agency (DLA) and suggests that an item is procured, stocked, and issued through the federal supply system. The NSN part CNA 2001-05 is recognized by the United States Department of Defense and the North Atlantic Treaty Organization (NATO). Not sure if this is what you’re looking for? No problem. To receive more information about NSN Number 5306015721907, please contact us at our toll-free number +1-714-705-4780 or email us at sales@nsn-sourcing.com.


NSN Information for Part Number CNA 2001-05 with NSN 5915-01-331-3906, 5915013313906

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5915-01-331-3906

Item Description:

Filter Radio Freque

59150133139060P
CIICHCCESDPMICCriticalityENAC
7 A
Part NumberISCRNVCRNCCHCCMSDSSADC
Cna 2001-05625

Characteristics Data of NSN 5915-01-331-3906, 5915013313906

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH6.080 INCHES MINIMUM AND 6.160 INCHES MAXIMUM
ADAQBODY LENGTH4.720 INCHES MINIMUM AND 4.760 INCHES MAXIMUM
ADATBODY WIDTH2.570 INCHES MINIMUM AND 2.610 INCHES MAXIMUM
ADAUBODY HEIGHT2.570 INCHES MINIMUM AND 2.610 INCHES MAXIMUM
AECRVIBRATION RESISTANCE RANGE IN HERTZ+10.0/+500.0
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.090 INCHES MINIMUM AND 1.110 INCHES MAXIMUM
AFGAOPERATING TEMP RANGE-54.0/+65.0 DEG CELSIUS
AFSVAVERAGE LIFE RATING IN HOURS1000.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTION125.0 OHMS 1ST RADIO INTERFERENCE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION125.0 OHMS 3RD RADIO INTERFERENCE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION125.0 OHMS 4TH RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION125.0 OHMS 1ST RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION125.0 OHMS 3RD RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION125.0 OHMS 4TH RADIO INTERFERENCE
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ20.0 1ST RADIO INTERFERENCE
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ20.0 3RD RADIO INTERFERENCE
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ20.0 4TH RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 2ND RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 4TH RADIO INTERFERENCE
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.2 VOLTS AC 1ST RADIO INTERFERENCE
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.2 VOLTS AC 3RD RADIO INTERFERENCE
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.2 VOLTS AC 4TH RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
AHCJFULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
AHCKFULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS1.5 AND 3.0 AND 78.0 AND 78.0 AND 100.0 AND 100.0
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE
CBBLFEATURES PROVIDEDFUNGUS RESISTANT AND SHOCK RESISTANT
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY4 THREADED STUD OUTPUT 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION15.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION15.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION15.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
CQJXNOMINAL THREAD SIZE0.164 INCHES
CQRGBODY MATERIALMETAL
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE500.0 VOLTS AT SEA LEVEL
PKWTUNPACKAGED UNIT WEIGHT3.000 POUNDS
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
AHAQSOURCE IMPEDANCE RATING PER FUNCTION125.0 OHMS 2ND RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION125.0 OHMS 2ND RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION15.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 3RD RADIO INTERFERENCE
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.2 VOLTS AC 2ND RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY2 THREADED STUD GROUND 3RD FUNCTION
AGAVEND ITEM IDENTIFICATIONTACTICAL AIR OPERATIONS MODULE
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ20.0 2ND RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 1ST RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY4 THREADED STUD INPUT 1ST FUNCTION
CRSTBODY SURFACE TREATMENTTIN
FEATSPECIAL FEATURESFOUR FILTERED FUNCTIONS

  Similar NATO Parts to CNA 2001-05

Upload RFQ Sheet
USA Flag

We are proud to supply every branch of the United States military


Why Choose Us?

Low Price Warrantied inventory at competitive prices
Find it Fast Search the world's largest inventory of electronic components by manufacturer, category or part number
Get it Fast All inventory ready to ship from our sellers
Quality Guaranteed We sell only warrantied and traceable parts
Semiconductor's Certifications and Memberships
The only independent
distributor with a
NO CHINA SOURCING Pledge
  • All Orders are Fulfilled in the U.S.A.
  • All shipments must comply with U.S.A export laws.
  • No exceptions.
Intrepid Fallen Heroes Fund

“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.

Thank You for Visiting NSN Sourcing.

If You’d Like to GET Quote For Latest NSN Parts, Just Fill The Instant RFQ Form And Get Reply Within 15 Minutes.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.