Are you in the market for 5950-01-081-2579 NSN parts such as 8 60009502, WE-3123 from manufactures like Senior Operations Llc, Wems Inc, Magnetika Inc? The National Stock Number (NSN) is a 13-digit serial number assigned by the US Defense Logistics Agency (DLA) to items that are procured, stocked, and issued through the federal supply system. Use our optimized search engine to find your required parts for NSN 5950-01-081-2579—then submit an instant RFQ for a quick, competitive quote. Here at NSN Sourcing, we make your purchasing process as simple and efficient as possible.
Part Number's List for NSN 5950-01-081-2579 | |
Item Name: | Transformer Power |
Federal Supply Class (FSC): | 5950 Coils and Transformers |
CAGE Code: | 03024, 26543, 15634 |
NIIN: | 010812579 |
Manufacturers: | Senior Operations Llc , Wems Inc , Magnetika Inc |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
8 60009502 | senior operations llc | transformer power | Avl | RFQ |
WE-3123 | wems inc | transformer power | Avl | RFQ |
WE-3123 | magnetika inc | transformer power | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 6.630 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.302 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 5.322 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.240 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.260 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 6.000 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 5.500 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.318 INCHES MINIMUM SINGLE GROUP AND 0.338 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 57.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 105.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 42.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 7 TAB, SOLDER LUG |
Low Price Warrantied inventory at competitive prices
Find it Fast Search the world's largest inventory of electronic components by manufacturer, category or part number
Quality Guaranteed We sell only warrantied and traceable parts
Get it Fast All inventory ready to ship from our sellers
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’d Like to GET Quote For Latest NSN Parts, Just Fill The Instant RFQ Form And Get Reply Within 15 Minutes.
Request for Quote