Item Name : Circuit Breaker
Manufacturer : Eaton Corporation
CAGE Code : 81640
FSC Details : 5925 circuit breakers
Good news! Part number 970-002-150 with NSN 5925013133895 by Eaton Corporation is available and ready to ship. NSN Sourcing, owned and operated by ASAP Semiconductor, offers the fastest lead times in the industry. If you are interested in ordering part number 970-002-150, leave your procurement process to us. Simply fill out the fields in the RFQ below. Your responses to the asterisk (*) marked fields are necessary in order to build your quote possible.
As a globally trusted distributor, our comprehensive inventory is unmatched across the aerospace and aviation, marine, railway, and defense industries. Owned and operated by ASAP Semiconductor, we have more than 10 million National Stock Numbers (NSN) in our ready-to-ship inventory. Our company is committed to quality, and we operate as an AS9120B, ISO 9001:2015, and FAA AC 0056B certified company.
Note : We will not share your information to any third parties.
With locations in the US, we provide an optimized purchasing solution to get the parts you need, when you need them. We have dedicated offices in California and Nevada.
A National Stock Number, or NATO Stock Number (NSN), is allocated by the Defense Logistics Agency (DLA) and suggests that an item is procured, stocked, and issued through the federal supply system. The NSN part 970-002-150 is recognized by the United States Department of Defense and the North Atlantic Treaty Organization (NATO). Not sure if this is what you’re looking for? No problem. To receive more information about NSN Number 5306015721907, please contact us at our toll-free number +1-714-705-4780 or email us at sales@nsn-sourcing.com.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-313-3895 Item Description: Circuit Breaker | 5925 | 013133895 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
970-002-150 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ABXD | BUSHING LENGTH | 0.235 INCHES MINIMUM AND 0.250 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 2.406 INCHES MINIMUM AND 2.468 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.189 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.045 INCHES MINIMUM AND 1.075 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKPX | POLE QUANTITY | 3 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC ALL LOCATIONS AND 30.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2500.0 AC ALL LOCATIONS AND 3000.0 DC ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 15.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | VIBRATION RESISTANT AND SHOCK RESISTANT |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CRTK | SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 100.0 AC AND 100.0 DC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 120.0 AC AND 28.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB W/SCREW |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.140 INCHES NOMINAL |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 150.0 AMPERES AC ALL LOCATIONS AND 150.0 AMPERES DC ALL LOCATIONS |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.219 INCHES MINIMUM AND 2.249 INCHES MAXIMUM |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 PUSH BUTTON |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.406 INCHES MINIMUM AND 1.468 INCHES MAXIMUM |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 3 ALARM |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT EACH POLE |
PKWT | UNPACKAGED UNIT WEIGHT | 130.0 GRAMS |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.